{"id":1473,"date":"2025-02-20T11:43:10","date_gmt":"2025-02-20T10:43:10","guid":{"rendered":"https:\/\/www.dadolab.com\/prodotti\/hp5-sonda-riscaldata\/"},"modified":"2026-07-07T10:17:24","modified_gmt":"2026-07-07T08:17:24","slug":"heated-isokinetic-probe-hp5","status":"publish","type":"prodotti","link":"https:\/\/www.dadolab.com\/en\/products\/heated-isokinetic-probe-hp5\/","title":{"rendered":"Heated Isokinetic Probe HP5"},"content":{"rendered":"\n\n<section id=\"media-text-block_c4860eaa5076e582fe199f22dfe2d77b\" class=\"block-media-text\">\n                    <div class=\"row g-5 align-items-center \">\n            <div class=\"col-lg-6\">\n                                                    <div class=\"block-media-text__image position-relative\">\n                        <figure><img decoding=\"async\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/MAIN__HP5-HP1-L-RISC.webp\" alt=\"\" class=\"w-100\" \/><\/figure>\n                                                    <div class=\"block-media-text__image-icons\">\n                                                                                                                                                <div class=\"block-media-text__image-icon\">\n                                            <img decoding=\"async\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/emissioni.png\" alt=\"\" \/>\n                                        <\/div>\n                                                                                                <\/div>\n                                            <\/div>\n                            <\/div>\n\n            <div class=\"col-lg-6 mt-6 mt-lg-0\">\n                                    <div class=\"desc-4 bg-gray-lighten badge\">Heated Isokinetic Probe<\/div>\n                                                    <h2 class=\"t-3 lh-1 my-5 exo-600\">HP5<\/h2>\n                                                    <div class=\"desc-2 my-5\"><p><span lang=\"en-US\"><b>HP5 &#8211; Advanced Isokinetic Sampling System for Particulate, Micropollutants, and PFAS<\/b><\/span><\/p>\n<\/div>\n                \n                                                    <div class=\"mt-5\">\n                        <a class=\"btn btn-primary\" href=\"https:\/\/suite.dadolab.com\/download\/hp5-heated-probe-isokinetic-stack-datasheet-101-102-hp5-en\" target=\"_blank\" rel=\"noopener\">Download Datasheet<\/a>\n                    <\/div>\n                            <\/div>\n        <\/div>\n    <\/section>\n\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\"><strong>HP5<\/strong> sets the benchmark for isokinetic sampling in full compliance with <strong>EN and EPA standards<\/strong>. Designed to deliver uncompromising precision, modularity, and ease of use, HP5 is the ideal solution for determining particulate matter, organic micropollutants, and compounds such as PFAS, dioxins, furans, and heavy metals.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">With its compact, robust design in <strong>AISI 316 stainless steel<\/strong>, HP5 guarantees resistance to corrosion and high temperatures, even in the most demanding environments. The system integrates all sampling lines into a single unit, featuring <strong>Swagelok connections<\/strong> for secure, leak-free performance. Automatic temperature control, managed by the <strong>ST5 sampler or an external unit<\/strong>, keeps the system above the dew point, preventing condensation and preserving sample integrity.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">HP5 is fully compatible with leading regulatory methods, including <strong>EN 13284-1, ISO 9096, EN ISO 1948-1, EPA Methods 5 and 23, ISO 11338-1, EN 13211, EN 14385, and OTM 45 PFAS<\/strong>. Its modular design enables simultaneous sampling of multiple pollutants, reducing time and costs. After filtration, titanium or glass collectors can be added to direct aliquots to derivative adsorption lines, ensuring compliance with official methods.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Engineered for field efficiency, HP5 combines ergonomics and practicality: integrated handles, a lightweight mounting system, and a rotating flange for quick installation on 4&#8243; to 5&#8243; nozzles. The sliding mechanism with rollers simplifies probe insertion and rotation, allowing fast and accurate swirl angle measurements. Weighing less than 1.5 kg, it offers portability without compromise.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Together with the <strong>ST5 automatic isokinetic sampler<\/strong>, HP5 forms the most complete and reliable solution for complex sampling campaigns. No imitation comes close\u2014HP5 is the ultimate choice for precision, efficiency, and regulatory compliance.<\/p>\n\n\n\n<div style=\"height:3rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n\n<section id=\"accordion-block_dbe9b066d8c995522c696eec2e6be9d0\" class=\"block-accordion\">\n            <div class=\"accordion custom-accordion my-4\" id=\"accordion-accordion-block_dbe9b066d8c995522c696eec2e6be9d0\">\n        \n            \n\n            <div class=\"accordion-item\">\n                <h2 class=\"accordion-header\">\n                    <button class=\"accordion-button fw-semibold desc-1 \" \n                            type=\"button\" \n                            data-bs-toggle=\"collapse\" \n                            data-bs-target=\"#collapse-0\" \n                            aria-expanded=\"true\" \n                            aria-controls=\"collapse-0\">\n                        Technical characteristics                    <\/button>\n                <\/h2>\n                <div id=\"collapse-0\" \n                     class=\"accordion-collapse collapse show\" \n                     data-bs-parent=\"#accordion-accordion-block_dbe9b066d8c995522c696eec2e6be9d0\">\n\n                                         <div class=\"accordion-body desc-2 blur-suite\">\n                                                    <div class=\"blur-suite-content\">\n                                                                <a href=\"https:\/\/suite.dadolab.com\/download\/hp5-heated-probe-isokinetic-stack-datasheet-101-102-hp5-en\" target=\"_blank\" class=\"btn btn-primary\" rel=\"noopener\">Visit Dado lab Suite<\/a>\n                                                            <\/div>\n                                                <table class=\"table has-desc-2-font-size\">\n<tbody>\n<tr>\n<td>Refrigerator power<\/td>\n<td>2360 Btu\/h<\/td>\n<\/tr>\n<tr>\n<td>Recirculation pump flowrate<\/td>\n<td>15 lt\/min @1.5 meters difference in height<\/td>\n<\/tr>\n<tr>\n<td>Bath temperature<\/td>\n<td>Preset on optimal values<\/td>\n<\/tr>\n<tr>\n<td>Operation conditions<\/td>\n<td>-10 \u00f7 +43\u00b0C, 95% RH<\/td>\n<\/tr>\n<tr>\n<td>Stock conditions<\/td>\n<td>-10 \u00f7 +50\u00b0C, 95% RH<\/td>\n<\/tr>\n<tr>\n<td>Bath size (W\u00d7D\u00d7H)<\/td>\n<td>270 \u00d7 170 \u00d7 160 mm<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>230 Vac \u00b110% 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Materials<\/td>\n<td>Steel and Aluminum<\/td>\n<\/tr>\n<tr>\n<td>Dimensions (W\u00d7D\u00d7H)<\/td>\n<td>390 \u00d7 270 \u00d7 505 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>16 kg<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>600 W<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n                    <\/div>\n                <\/div>\n            <\/div>\n                <\/div>\n    <\/section>\n\n\n\n\n\n<section id=\"gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\" class=\"my-6 block-gallery\">\n        \n                        \n                <a class=\"block-gallery__container --x5\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\" href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/MAIN__HP5-HP1-L-RISC.webp\">\n                    <div class=\"block-gallery__grid\">\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/MAIN__HP5-HP1-L-RISC-768x593.webp\" \n                                    alt=\"\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/HP5_HP1_FC5_001-768x549.webp\" \n                                    alt=\"\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/101-102-1103-Hub-4-Derivati-768x618.webp\" \n                                    alt=\"\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/sonda-vasca_fc5.webp\" \n                                    alt=\"\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/PFAS-5-768x614.webp\" \n                                    alt=\"\" \/>\n                            <\/div>\n                                            <\/div>\n                    <span class=\"block-gallery__button desc-2\">View all images<\/span>\n                <\/a>\n\n                <!-- Aggiungiamo link nascosti per tutte le immagini -->\n                                <div class=\"d-none\">\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/HP5_HP1_FC5_001.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/101-102-1103-Hub-4-Derivati.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/sonda-vasca_fc5.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/PFAS-5.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/PFAS.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/HP5-HUB.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/Flange-Afnor__Dado-Slide-and-lock.webp\" data-fslightbox=\"gallery-gallery-block_bb8ee58cb1f13fadad4e18ae86b09df6\"><\/a>\n                                    <\/div>\n                \n            \n        \n<\/section>\n\n","protected":false},"excerpt":{"rendered":"<p>HP5 sets the benchmark for isokinetic sampling in full compliance with EN and EPA standards. Designed to deliver uncompromising precision, modularity, and ease of use, HP5 is the ideal solution for determining particulate matter, organic micropollutants, and compounds such as PFAS, dioxins, furans, and heavy metals. With its compact, robust design in AISI 316 stainless [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2663,"comment_status":"open","ping_status":"closed","template":"","categoria_prodotti":[32],"class_list":["post-1473","prodotti","type-prodotti","status-publish","has-post-thumbnail","hentry","categoria_prodotti-sampling-probes"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/prodotti\/1473","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/prodotti"}],"about":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/types\/prodotti"}],"author":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/comments?post=1473"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/media\/2663"}],"wp:attachment":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/media?parent=1473"}],"wp:term":[{"taxonomy":"categoria_prodotti","embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/categoria_prodotti?post=1473"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}