{"id":2422,"date":"2025-12-02T11:02:04","date_gmt":"2025-12-02T10:02:04","guid":{"rendered":"https:\/\/www.dadolab.com\/?post_type=prodotti&#038;p=2422"},"modified":"2026-07-07T10:12:44","modified_gmt":"2026-07-07T08:12:44","slug":"gd1-r-compact-rack-mount-gas-dryer-for-continuous-operation","status":"publish","type":"prodotti","link":"https:\/\/www.dadolab.com\/en\/products\/gd1-r-compact-rack-mount-gas-dryer-for-continuous-operation\/","title":{"rendered":"GD1-R: Compact rack-mount gas dryer for continuous operation"},"content":{"rendered":"\n\n<section id=\"media-text-block_2e82bb525a04189352b78da9f44ee0e1\" class=\"block-media-text\">\n                    <div class=\"row g-5 align-items-center \">\n            <div class=\"col-lg-6\">\n                                                    <div class=\"block-media-text__image position-relative\">\n                        <figure><img decoding=\"async\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-R-Rack-mounted-cooling-system-for-continuous-applications.webp\" alt=\"GD1-R Rack mounted cooling system for continuous applications - Dado lab\" class=\"w-100\" \/><\/figure>\n                                                    <div class=\"block-media-text__image-icons\">\n                                                                                                                                                <div class=\"block-media-text__image-icon\">\n                                            <img decoding=\"async\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/emissioni.png\" alt=\"\" \/>\n                                        <\/div>\n                                                                                                                                                                                                        <\/div>\n                                            <\/div>\n                            <\/div>\n\n            <div class=\"col-lg-6 mt-6 mt-lg-0\">\n                                    <div class=\"desc-4 bg-gray-lighten badge\">Gas Dryer<\/div>\n                                                    <h2 class=\"t-3 lh-1 my-5 exo-600\">GD1-R<\/h2>\n                                                    <div class=\"desc-2 my-5\"><p>Designed for rack mounting and continuous operation, the <strong>GD1-R<\/strong> is the <strong>conditioning system<\/strong> that ensures precise dew point control and complete protection of downstream analyzers.<\/p>\n<\/div>\n                \n                                                    <div class=\"mt-5\">\n                        <a class=\"btn btn-primary\" href=\"https:\/\/suite.dadolab.com\/download\/gd1r-rack-cooling-system-cems-datasheet-101-105-gd1r-en\" target=\"_blank\" rel=\"noopener\">Download Datasheet<\/a>\n                    <\/div>\n                            <\/div>\n        <\/div>\n    <\/section>\n\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Its automatic control activates sampling only when the set point is reached, preventing unwanted condensation.<br>Compliant with&nbsp;<strong>EN 15058:2017<\/strong>, it maintains a dew point below&nbsp;<strong>4\u00b0C<\/strong>&nbsp;in the flow stream, regardless of incoming humidity.<br>Dew point data can be integrated into&nbsp;<strong>PLC or other data acquisition systems<\/strong>&nbsp;for full process monitoring.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Thanks to its&nbsp;<strong>inverter-based compression system<\/strong>, the GD1-R dynamically adjusts cooling capacity in real time, leveraging a&nbsp;<strong>custom-designed heat exchanger<\/strong>&nbsp;for maximum efficiency across applications.<br>Compact and easy to integrate, it quickly replaces existing systems and guarantees reliability even with gas containing up to&nbsp;<strong>40% humidity<\/strong>, making it ideal for harsh, high-moisture environments.<br>It features&nbsp;<strong>two configurable condensation modules<\/strong>, each operating independently to handle gases from separate circuits using a single compressor.<\/p>\n\n\n\n<div style=\"height:3rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-gray-dark-color has-text-color has-link-color wp-elements-1\">Technical Characteristics<\/h2>\n\n\n\n\n<section id=\"accordion-block_005ba77609d80cefcda4518a4042812f\" class=\"block-accordion\">\n            <div class=\"accordion custom-accordion my-4\" id=\"accordion-accordion-block_005ba77609d80cefcda4518a4042812f\">\n        \n            \n\n            <div class=\"accordion-item\">\n                <h2 class=\"accordion-header\">\n                    <button class=\"accordion-button fw-semibold desc-1 \" \n                            type=\"button\" \n                            data-bs-toggle=\"collapse\" \n                            data-bs-target=\"#collapse-0\" \n                            aria-expanded=\"true\" \n                            aria-controls=\"collapse-0\">\n                        General features                    <\/button>\n                <\/h2>\n                <div id=\"collapse-0\" \n                     class=\"accordion-collapse collapse show\" \n                     data-bs-parent=\"#accordion-accordion-block_005ba77609d80cefcda4518a4042812f\">\n\n                                         <div class=\"accordion-body desc-2 blur-suite\">\n                                                    <div class=\"blur-suite-content\">\n                                                                <a href=\"https:\/\/suite.dadolab.com\/download\/gd1r-rack-cooling-system-cems-datasheet-101-105-gd1r-en\" target=\"_blank\" class=\"btn btn-primary\" rel=\"noopener\">Visit Dado lab Suite<\/a>\n                                                            <\/div>\n                                                <table class=\"table has-desc-2-font-size\">\n<tbody>\n<tr>\n<td>Refrigeration unit<\/td>\n<td>Inverter Compressor<\/td>\n<\/tr>\n<tr>\n<td>Cooling capacity<\/td>\n<td>Max 460W<\/td>\n<\/tr>\n<tr>\n<td>Refrigerant<\/td>\n<td>R134a<\/td>\n<\/tr>\n<tr>\n<td>Condensation temperature<\/td>\n<td>2\u00b0C (freely programmable)<\/td>\n<\/tr>\n<tr>\n<td>Hysteresis<\/td>\n<td>\u00b1 1\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Condensate drain<\/td>\n<td>Peristaltic pump (n\u00b02 for 2W model)<\/td>\n<\/tr>\n<tr>\n<td>Tube material<\/td>\n<td>Novoprene (with quick change release)<\/td>\n<\/tr>\n<tr>\n<td>Flowrate<\/td>\n<td>14 ml\/min<\/td>\n<\/tr>\n<tr>\n<td>Condensed In\/Out connections<\/td>\n<td>Hose connector diam. 6 mm for Viton hose 4\/6 mm<\/td>\n<\/tr>\n<tr>\n<td>Dew point temperature sensor<\/td>\n<td>Type K thermocouple<\/td>\n<\/tr>\n<tr>\n<td>Connector<\/td>\n<td>TC K std 2Pin compensated socket \u2013 cable length 1m<\/td>\n<\/tr>\n<tr>\n<td>Control panel<\/td>\n<td>Refrigerated bath temperature, condensation temperature setpoint, alarm setpoint<\/td>\n<\/tr>\n<tr>\n<td>Status lamp<\/td>\n<td>Green LED for \u201cReady\u201d<\/td>\n<\/tr>\n<tr>\n<td>Status and remote start contacts<\/td>\n<td>Clean Relay contact for alarm signaling<\/td>\n<\/tr>\n<tr>\n<td>Remote start<\/td>\n<td>Remote start\/stop input (OPTIONAL)<\/td>\n<\/tr>\n<tr>\n<td>Frame<\/td>\n<td>Powder-coated aluminum<\/td>\n<\/tr>\n<tr>\n<td>Operating conditions<\/td>\n<td>-6 \u00f7 +35\u00b0C 96% RH<\/td>\n<\/tr>\n<tr>\n<td>Storage conditions<\/td>\n<td>-10 \u00f7 +40\u00b0C 96% RH<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>230 or 110 Vac \u00b110% 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Consumption<\/td>\n<td>Max 1.5A<\/td>\n<\/tr>\n<tr>\n<td>Dimensions<\/td>\n<td>316 \u00d7 280 \u00d7 390 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight<\/td>\n<td>7.5 kg (without peristaltic and condensers)<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">AISI316 condenser<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Gas inlet\/outlet connections<\/td>\n<td>AISI 316 fittings with double ogive tube 6mm diameter<\/td>\n<\/tr>\n<tr>\n<td>Dew point temp. sensor connections<\/td>\n<td>AISI 316 fittings with double ogive tube 6mm diameter<\/td>\n<\/tr>\n<tr>\n<td>Condensate outlet connections<\/td>\n<td>PVDF fitting for Viton pipe 4\/6 mm<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Glass condenser<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Gas inlet\/outlet connections<\/td>\n<td>Schott GL 14 for PTFE Tube 6mm<\/td>\n<\/tr>\n<tr>\n<td>Dew point temp. sensor connections<\/td>\n<td>Schott GL 14 for PTFE Tube 6mm<\/td>\n<\/tr>\n<tr>\n<td>Condensate outlet connections<\/td>\n<td>Schott GL 14 for PTFE Tube 6mm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n                    <\/div>\n                <\/div>\n            <\/div>\n                <\/div>\n    <\/section>\n\n\n\n\n\n<section id=\"gallery-block_e1cca5a43982a43b8ff135dd060198b0\" class=\"my-6 block-gallery\">\n        \n                        \n                <a class=\"block-gallery__container --x3\" data-fslightbox=\"gallery-gallery-block_e1cca5a43982a43b8ff135dd060198b0\" href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-R-Rack-mounted-cooling-system-for-continuous-applications.webp\">\n                    <div class=\"block-gallery__grid\">\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-R-Rack-mounted-cooling-system-for-continuous-applications-768x693.webp\" \n                                    alt=\"GD1-R Rack mounted cooling system for continuous applications - Dado lab\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-R21-2-768x614.webp\" \n                                    alt=\"GD1-R21 - Dado lab\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-RACK-dimensions-768x543.webp\" \n                                    alt=\"GD1 RACK - dimensions - Dado lab\" \/>\n                            <\/div>\n                                            <\/div>\n                    <span class=\"block-gallery__button desc-2\">View all images<\/span>\n                <\/a>\n\n                <!-- Aggiungiamo link nascosti per tutte le immagini -->\n                                <div class=\"d-none\">\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-R21-2.webp\" data-fslightbox=\"gallery-gallery-block_e1cca5a43982a43b8ff135dd060198b0\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/12\/GD1-RACK-dimensions.webp\" data-fslightbox=\"gallery-gallery-block_e1cca5a43982a43b8ff135dd060198b0\"><\/a>\n                                    <\/div>\n                \n            \n        \n<\/section>\n\n","protected":false},"excerpt":{"rendered":"<p>Its automatic control activates sampling only when the set point is reached, preventing unwanted condensation.Compliant with&nbsp;EN 15058:2017, it maintains a dew point below&nbsp;4\u00b0C&nbsp;in the flow stream, regardless of incoming humidity.Dew point data can be integrated into&nbsp;PLC or other data acquisition systems&nbsp;for full process monitoring. Thanks to its&nbsp;inverter-based compression system, the GD1-R dynamically adjusts cooling capacity [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":2411,"comment_status":"open","ping_status":"closed","template":"","categoria_prodotti":[30,28],"class_list":["post-2422","prodotti","type-prodotti","status-publish","has-post-thumbnail","hentry","categoria_prodotti-gas-conditioning-and-sampling","categoria_prodotti-cooling-condensing-devices"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/prodotti\/2422","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/prodotti"}],"about":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/types\/prodotti"}],"author":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/comments?post=2422"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/media\/2411"}],"wp:attachment":[{"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/media?parent=2422"}],"wp:term":[{"taxonomy":"categoria_prodotti","embeddable":true,"href":"https:\/\/www.dadolab.com\/en\/wp-json\/wp\/v2\/categoria_prodotti?post=2422"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}