{"id":3160,"date":"2025-02-18T11:56:59","date_gmt":"2025-02-18T10:56:59","guid":{"rendered":"https:\/\/www.dadolab.com\/prodotti\/st5-and-st5-evo-isokinetic-automatic-sampler\/"},"modified":"2026-07-07T10:45:14","modified_gmt":"2026-07-07T08:45:14","slug":"st5-et-st5-evo-l-echantillonneur-isocinetique-automatique","status":"publish","type":"prodotti","link":"https:\/\/www.dadolab.com\/fr\/produits\/st5-et-st5-evo-l-echantillonneur-isocinetique-automatique\/","title":{"rendered":"ST5 et ST5-EVO: l\u2019\u00e9chantillonneur isocin\u00e9tique automatique"},"content":{"rendered":"\n\n<section id=\"media-text-block_21cf84df69e7f86cfa4a8885e88e85a8\" class=\"block-media-text\">\n                    <div class=\"row g-5 align-items-center \">\n            <div class=\"col-lg-6\">\n                                                    <div class=\"block-media-text__image position-relative\">\n                        <figure><img decoding=\"async\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-Famille.webp\" alt=\"ST5 Famille - Dado lab\" class=\"w-100\" \/><\/figure>\n                                                    <div class=\"block-media-text__image-icons\">\n                                                                                                                                                <div class=\"block-media-text__image-icon\">\n                                            <img decoding=\"async\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/emissioni.png\" alt=\"\" \/>\n                                        <\/div>\n                                                                                                <\/div>\n                                            <\/div>\n                            <\/div>\n\n            <div class=\"col-lg-6 mt-6 mt-lg-0\">\n                                    <div class=\"desc-4 bg-gray-lighten badge\">\u00c9chantillonneur isocin\u00e9tique automatique<\/div>\n                                                    <h2 class=\"t-3 lh-1 my-5 exo-600\">ST5<\/h2>\n                                                    <div class=\"desc-2 my-5\"><p><b>ST5 LT : L&rsquo;essence du ST5,\u00a0<span class=\"il\">la<\/span>\u00a0l\u00e9g\u00e8ret\u00e9 en plus.<br \/>\n<\/b><\/p>\n<p>Le\u00a0<b>ST5 LT<\/b> est un pr\u00e9leveur isocin\u00e9tique automatique sp\u00e9cifiquement con\u00e7u pour l\u2019\u00e9chantillonnage des \u00e9missions avec des sondes non chauff\u00e9es ou auto-chauff\u00e9es.<\/p>\n<\/div>\n                \n                                                    <div class=\"mt-5\">\n                        <a class=\"btn btn-primary\" href=\"https:\/\/suite.dadolab.com\/download\/st5-st5evo-datasheet-101-101-st5-fr\" target=\"_blank\" rel=\"noopener\">T\u00e9l\u00e9charger la fiche technique<\/a>\n                    <\/div>\n                            <\/div>\n        <\/div>\n    <\/section>\n\n\n\n\n<div style=\"height:2rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Il partage&nbsp;la&nbsp;m\u00eame plateforme mat\u00e9rielle (<strong>hardware<\/strong>) et logicielle (<strong>firmware<\/strong>) que le mod\u00e8le ST5 standard, \u00e0 quelques exceptions cl\u00e9s : il ne dispose pas de r\u00e9gulation thermique, pr\u00e9sente un circuit pneumatique o\u00f9 le compteur volum\u00e9trique fonctionne \u00e0 pression ambiante, et peut \u00eatre aliment\u00e9 par batterie.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Malgr\u00e9 sa configuration simplifi\u00e9e, le&nbsp;<strong>ST5 LT<\/strong>&nbsp;reste enti\u00e8rement automatique et int\u00e8gre l&rsquo;ensemble des calculs isocin\u00e9tiques, des fonctions et des fonctionnalit\u00e9s de gestion du ST5.<\/p>\n\n\n\n<p class=\"has-desc-2-font-size wp-block-paragraph\">Cela garantit une pr\u00e9cision \u00e9lev\u00e9e, en faisant une alternative fiable et performante aux syst\u00e8mes plus complexes.<\/p>\n\n\n\n<div style=\"height:3rem\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-gray-dark-color has-text-color has-link-color wp-elements-1\">Caract\u00e9ristiques techniques<\/h2>\n\n\n\n\n<section id=\"accordion-block_7bbc123fcd8b17eadab962797948419a\" class=\"block-accordion\">\n            <div class=\"accordion custom-accordion my-4\" id=\"accordion-accordion-block_7bbc123fcd8b17eadab962797948419a\">\n        \n            \n\n            <div class=\"accordion-item\">\n                <h2 class=\"accordion-header\">\n                    <button class=\"accordion-button fw-semibold desc-1 \" \n                            type=\"button\" \n                            data-bs-toggle=\"collapse\" \n                            data-bs-target=\"#collapse-0\" \n                            aria-expanded=\"true\" \n                            aria-controls=\"collapse-0\">\n                        General                    <\/button>\n                <\/h2>\n                <div id=\"collapse-0\" \n                     class=\"accordion-collapse collapse show\" \n                     data-bs-parent=\"#accordion-accordion-block_7bbc123fcd8b17eadab962797948419a\">\n\n                                         <div class=\"accordion-body desc-2 blur-suite\">\n                                                    <div class=\"blur-suite-content\">\n                                                                <a href=\"https:\/\/suite.dadolab.com\/download\/st5-st5evo-datasheet-101-101-st5-fr\" target=\"_blank\" class=\"btn btn-primary\" rel=\"noopener\">Visit Dado lab Suite<\/a>\n                                                            <\/div>\n                                                <table class=\"table has-desc-2-font-size\">\n<tbody>\n<tr>\n<td>Operating range<\/td>\n<td>5 \u00f7 60 l\/min<\/td>\n<\/tr>\n<tr>\n<td>Sampled gas condition<\/td>\n<td>Dehumidified, max temperature 45\u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Gas inlet<\/td>\n<td>With particulate and liquid protection filter<\/td>\n<\/tr>\n<tr>\n<td>Connections<\/td>\n<td>Quick couplings<\/td>\n<\/tr>\n<tr>\n<td>Operating conditions<\/td>\n<td>-20 \u00f7 45\u00b0C, 95% RH<\/td>\n<\/tr>\n<tr>\n<td>Storage conditions<\/td>\n<td>-10 \u00f7 50\u00b0C, 95% RH<\/td>\n<\/tr>\n<tr>\n<td>Display<\/td>\n<td>3.5\u201d Graphic LCD (QVGA)<\/td>\n<\/tr>\n<tr>\n<td>Data port<\/td>\n<td>USB 2.0, Bluetooth<\/td>\n<\/tr>\n<tr>\n<td>Internal memory<\/td>\n<td>16 GB<\/td>\n<\/tr>\n<tr>\n<td>Power supply<\/td>\n<td>230 Vac \u00b110% 50\/60Hz<\/td>\n<\/tr>\n<tr>\n<td>Materials<\/td>\n<td>Structure composed of steel and aluminum<\/td>\n<\/tr>\n<tr>\n<td>Keyboard<\/td>\n<td>Polycarbonate, tactile effect keys<\/td>\n<\/tr>\n<tr>\n<td>Dimensions ST5<\/td>\n<td>390 \u00d7 264 \u00d7 506 mm<\/td>\n<\/tr>\n<tr>\n<td>Dimensions ST5 EVO CU<\/td>\n<td>390 \u00d7 264 \u00d7 386 mm<\/td>\n<\/tr>\n<tr>\n<td>Dimensions ST5 EVO PU<\/td>\n<td>227 \u00d7 329 \u00d7 191 mm<\/td>\n<\/tr>\n<tr>\n<td>Weight ST5 pump 4.5 m\u00b3\/h<\/td>\n<td>22 kg<\/td>\n<\/tr>\n<tr>\n<td>Weight ST5 pump 8.5 m\u00b3\/h<\/td>\n<td>24 kg<\/td>\n<\/tr>\n<tr>\n<td>Weight ST5 EVO CU<\/td>\n<td>13 kg<\/td>\n<\/tr>\n<tr>\n<td>Weight ST5 EVO PU pump 4.5 m\u00b3\/h<\/td>\n<td>10 kg<\/td>\n<\/tr>\n<tr>\n<td>Weight ST5 EVO PU pump 8.5 m\u00b3\/h<\/td>\n<td>11.5 kg<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Measurement and sensor characteristics<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Sampled volume<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>DGM<\/td>\n<td>Class G2.5 EN 1359 compliant<\/td>\n<\/tr>\n<tr>\n<td>Flow range<\/td>\n<td>0.025 m\u00b3\/h \u00f7 4.0 m\u00b3\/h<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>2% reading<\/td>\n<\/tr>\n<tr>\n<td>Encoder resolution<\/td>\n<td>0.1 liters<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Sampling flowrate<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Control type<\/td>\n<td>Orifice mass flow meter, compliant with UNI EN ISO 5167-2<\/td>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td>5 \u00f7 60 l\/min<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 l\/min<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>\u00b1 1%<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Pitot differential pressure<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td>-100 \u00f7 1000 Pa (-10 \u00f7 100 mmH\u2082O)<\/td>\n<\/tr>\n<tr>\n<td>Linearity and hysteresis (combined)<\/td>\n<td>0.25 % FS<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>Better than 1% of measurement (\u00b1 2 Pa)<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 Pa (0.005 mmH\u2082O)<\/td>\n<\/tr>\n<tr>\n<td>Maximum burst pressure<\/td>\n<td>Max 3000 Pa (300 mmH\u2082O)<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Absolute pressure (static-barometric)<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td>10 \u00f7 105 kPa (1050 mBar)<\/td>\n<\/tr>\n<tr>\n<td>Linearity and hysteresis (combined)<\/td>\n<td>0.25 % FS<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.01 kPa (0.1 mBar)<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>Better than 1% of measurement (\u00b1 0.25 kPa)<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">Thermocouple input<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td>-20 \u00f7 1200 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1% reading \u00b1 0.4 \u00b0C<\/td>\n<\/tr>\n<tr class=\"border-white\">\n<td><\/td>\n<td><\/td>\n<\/tr>\n<tr>\n<th class=\"text-uppercase\">DGM temperature<\/th>\n<th><\/th>\n<\/tr>\n<tr>\n<td>Range<\/td>\n<td>-20 \u00f7 100 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Resolution<\/td>\n<td>0.1 \u00b0C<\/td>\n<\/tr>\n<tr>\n<td>Accuracy<\/td>\n<td>1% reading \u00b1 0.2 \u00b0C<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n                    <\/div>\n                <\/div>\n            <\/div>\n                <\/div>\n    <\/section>\n\n\n\n\n\n<section id=\"gallery-block_a09cac2200401676e661af21143e95a8\" class=\"my-6 block-gallery\">\n        \n                        \n                <a class=\"block-gallery__container --x5\" data-fslightbox=\"gallery-gallery-block_a09cac2200401676e661af21143e95a8\" href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-Famille.webp\">\n                    <div class=\"block-gallery__grid\">\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-Famille-768x594.webp\" \n                                    alt=\"ST5 Famille - Dado lab\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/Evo-CU-et-SU-768x614.webp\" \n                                    alt=\"Evo - CU et SU - Dado lab\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-01-768x614.webp\" \n                                    alt=\"ST5 01 - Dado lab\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/Panneau-ST5-rev2-768x614.webp\" \n                                    alt=\"Panneau ST5 - rev2 - Dado lab\" \/>\n                            <\/div>\n                                                    <div class=\"block-gallery__grid-item\">\n                                <img decoding=\"async\" class=\"w-100 h-100 object-fit-cover\" src=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-Mise-a-jour-du-firmware-768x536.webp\" \n                                    alt=\"ST5 Mise a jour du firmware - Dado lab\" \/>\n                            <\/div>\n                                            <\/div>\n                    <span class=\"block-gallery__button desc-2\">Voir toutes les images<\/span>\n                <\/a>\n\n                <!-- Aggiungiamo link nascosti per tutte le immagini -->\n                                <div class=\"d-none\">\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/Evo-CU-et-SU.webp\" data-fslightbox=\"gallery-gallery-block_a09cac2200401676e661af21143e95a8\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-01.webp\" data-fslightbox=\"gallery-gallery-block_a09cac2200401676e661af21143e95a8\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/Panneau-ST5-rev2.webp\" data-fslightbox=\"gallery-gallery-block_a09cac2200401676e661af21143e95a8\"><\/a>\n                                        <a href=\"https:\/\/www.dadolab.com\/wp-content\/uploads\/2025\/02\/ST5-Mise-a-jour-du-firmware.webp\" data-fslightbox=\"gallery-gallery-block_a09cac2200401676e661af21143e95a8\"><\/a>\n                                    <\/div>\n                \n            \n        \n<\/section>\n\n","protected":false},"excerpt":{"rendered":"<p>Il partage&nbsp;la&nbsp;m\u00eame plateforme mat\u00e9rielle (hardware) et logicielle (firmware) que le mod\u00e8le ST5 standard, \u00e0 quelques exceptions cl\u00e9s : il ne dispose pas de r\u00e9gulation thermique, pr\u00e9sente un circuit pneumatique o\u00f9 le compteur volum\u00e9trique fonctionne \u00e0 pression ambiante, et peut \u00eatre aliment\u00e9 par batterie. Malgr\u00e9 sa configuration simplifi\u00e9e, le&nbsp;ST5 LT&nbsp;reste enti\u00e8rement automatique et int\u00e8gre l&rsquo;ensemble des [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":3165,"comment_status":"open","ping_status":"closed","template":"","categoria_prodotti":[53],"class_list":["post-3160","prodotti","type-prodotti","status-publish","has-post-thumbnail","hentry","categoria_prodotti-echantillonneurs-demissions"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/prodotti\/3160","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/prodotti"}],"about":[{"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/types\/prodotti"}],"author":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/comments?post=3160"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/media\/3165"}],"wp:attachment":[{"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/media?parent=3160"}],"wp:term":[{"taxonomy":"categoria_prodotti","embeddable":true,"href":"https:\/\/www.dadolab.com\/fr\/wp-json\/wp\/v2\/categoria_prodotti?post=3160"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}